ASTM A213 TP304L Seamless Heat Exchanger Tube, Annealed | S30403

Place of Origin: china
Brand Name: Shangyou
Certification: ISO9001
Model Number: ASTM A213 TP304L Seamless Heat Exchanger Tube, Annealed | S30403
Minimum Order Quantity: 5Ton
Price: Based on grade, size, surface, processing, quantity and current raw material market price.
Packaging Details: Standard seaworthy export packing with bundles, waterproof wrapping, pallets or wooden cases.
Delivery Time: 7-15
Payment Terms: L/C,D/A,D/P,T/T
Supply Ability: Stock supply, regular production and custom manufacturing available.
Inquiry Now
Get A Quote
Specifications
Highlight Features

ASTM A213 TP304L seamless tube

,

heat exchanger tube S30403

,

annealed stainless steel pipe

Material Standard:
ASTM A213/A213M — Confirm The Latest Contract Edition At PO Stage
Grade / UNS:
TP304L / S30403
Product Form:
Seamless Tube
Ordered Condition:
Solution Annealed; Final Condition And Heat Treatment Records To The Ordered Edition.
Dimensions:
Common RFQ ODs Include 12.7, 15.88, 19.05, 25.4 And 31.75 Mm. Wall And Length Must Be Stated; All Dimensions Remain Subject To Mill Confirmation.
Surface / Ends:
Pickled/annealed Or Bright Annealed Where Available; ID Cleanliness And Roughness By PO.
Manufacturing Route:
Hot- Or Cold-finished Seamless Manufacture, Followed By Required Heat Treatment, Straightening And End Preparation.
Inspection Package:
Chemical And Mechanical Tests, Hydrostatic Or Permitted NDE, Eddy-current Testing When Ordered, Dimensional Checks And EN 10204 3.1 Documentation When Contracted.
Product Description

ASTM A213 TP304L Seamless Heat Exchanger Tube, Annealed | S30403
Shaanxi Shangyou Stainless Steel Co., Ltd. supplies astm a213 tp304l seamless heat exchanger tube, annealed | s30403 for buyers whose primary search intent is heat-exchanger and boiler tubing, not generic stainless or nickel-alloy stock. The page should be quoted against the selected standard edition, the equipment or component drawing and the governing design code. Seamless austenitic stainless tube for boiler, superheater and heat-exchanger service under ASTM A213/A213M.

The material decision should start with service conditions. Low-carbon 18Cr-8Ni austenitic stainless steel. The low carbon level helps limit sensitization after welding. Choose TP316L when molybdenum is needed for better localized-corrosion resistance in chloride-bearing media. This comparison belongs in the enquiry stage because a higher alloy name does not automatically deliver the lowest life-cycle risk.

A complete RFQ needs product form, grade/UNS, ordered condition, dimensional basis, tolerances, quantity and inspection level. Common RFQ ODs include 12.7, 15.88, 19.05, 25.4 and 31.75 mm. Wall and length must be stated; all dimensions remain subject to mill confirmation. For pressure-containing products, the material standard controls product quality; it does not replace pressure-design calculations, corrosion allowance or code approval.

Manufacturing and documentation must remain connected. Hot- or cold-finished seamless manufacture, followed by required heat treatment, straightening and end preparation. The baseline verification plan is: Chemical and mechanical tests, hydrostatic or permitted NDE, eddy-current testing when ordered, dimensional checks and EN 10204 3.1 documentation when contracted. Any supplementary requirement—PMI extent, UT class, eddy-current acceptance, corrosion testing, grain size, roughness, cleanliness or third-party inspection—must appear in the PO before production.

Fabrication guidance: Good weldability with qualified procedures. Control heat tint, purge quality and post-fabrication cleaning on wetted surfaces. Selection boundary: TP304L is not a default choice for seawater, concentrated chlorides or strongly reducing acids. Corrosion selection must use actual fluid chemistry, temperature and crevice conditions. Buyers should provide fluid composition, maximum and minimum temperature, pressure, design life, fabrication route and applicable code so the quotation can separate mandatory requirements from optional controls.

Standards, Dimensions and Supply Definition
Material standard ASTM A213/A213M — confirm the latest contract edition at PO stage
Grade / UNS TP304L / S30403
Product form Seamless tube
Ordered condition Solution annealed; final condition and heat treatment records to the ordered edition.
Dimensions Common RFQ ODs include 12.7, 15.88, 19.05, 25.4 and 31.75 mm. Wall and length must be stated; all dimensions remain subject to mill confirmation.
Surface / ends Pickled/annealed or bright annealed where available; ID cleanliness and roughness by PO.
Manufacturing route Hot- or cold-finished seamless manufacture, followed by required heat treatment, straightening and end preparation.
Inspection package Chemical and mechanical tests, hydrostatic or permitted NDE, eddy-current testing when ordered, dimensional checks and EN 10204 3.1 documentation when contracted.


Material and Selection Markers
Marker Typical / controlled basis Buyer implication
Cr–Ni balance Approx. 18Cr-8Ni family General oxidation and corrosion resistance
Carbon Low-carbon L grade Reduces weld-related sensitization risk
Molybdenum Not intentionally alloyed Less pitting resistance than TP316L


Use note: Values above are concise identification/selection markers, not a replacement for the ordered ASTM/AWS chemistry table or the MTC.

Candidate Applications
  • Shell-and-tube exchangers.
  • Condensers.
  • Food and beverage heat-transfer equipment.
  • Low-chloride utility service.
Buyer Decision Boundary

Choose TP316L when molybdenum is needed for better localized-corrosion resistance in chloride-bearing media.

Do not overclaim: TP304L is not a default choice for seawater, concentrated chlorides or strongly reducing acids. Corrosion selection must use actual fluid chemistry, temperature and crevice conditions.
Processing, Inspection and Documentation
  • Manufacturing: Hot- or cold-finished seamless manufacture, followed by required heat treatment, straightening and end preparation.
  • Fabrication: Good weldability with qualified procedures. Control heat tint, purge quality and post-fabrication cleaning on wetted surfaces.
  • Inspection: Chemical and mechanical tests, hydrostatic or permitted NDE, eddy-current testing when ordered, dimensional checks and EN 10204 3.1 documentation when contracted.
  • Traceability: Keep heat/lot identity through cutting, machining, bending, welding, testing and packing.
  • Documentation: Confirm MTC type, test reports, packing list, country-of-origin statement and third-party inspection before production.
RFQ Checklist
  • Standard and adopted edition: ASTM A213/A213M
  • Grade / UNS: TP304L / S30403
  • Form and route: Seamless tube
  • Dimensions, tolerances, quantity and unit basis
  • Delivery/heat-treatment condition and surface/end finish
  • Design code, service fluid/atmosphere, pressure and temperature
  • Inspection/NDE, acceptance criteria, MTC and third-party witness points
  • Marking, preservation, packing and delivery destination
Inquiry CTA
Send Shaanxi Shangyou Stainless Steel Co., Ltd. your ASTM A213/A213M / TP304L RFQ with dimensions, condition, quantity, inspection level and service data. We will return a specification review, capability confirmation and quotation basis without substituting grade, route or test scope silently.
Frequently Asked Questions

1. What does ASTM A213/A213M cover for this product?

Seamless austenitic stainless tube for boiler, superheater and heat-exchanger service under ASTM A213/A213M. Always purchase to the edition adopted by the contract or project specification.

2. Is this product seamless, welded, forged, rolled or drawn?

The PO must state the required route exactly: Seamless tube. Do not rely on a product photograph or a family name to establish the route.

3. How should buyers select TP304L?

Low-carbon 18Cr-8Ni austenitic stainless steel. The low carbon level helps limit sensitization after welding. Choose TP316L when molybdenum is needed for better localized-corrosion resistance in chloride-bearing media.

4. Which dimensions must be included in the RFQ?

Common RFQ ODs include 12.7, 15.88, 19.05, 25.4 and 31.75 mm. Wall and length must be stated; all dimensions remain subject to mill confirmation. Add quantity, unit basis, tolerances and any drawing-controlled geometry.

5. What heat-treatment or delivery condition is required?

Solution annealed; final condition and heat treatment records to the ordered edition. The MTC and heat-treatment records should use the same grade and condition language as the PO.

6. Which inspection documents can be requested?

Chemical and mechanical tests, hydrostatic or permitted NDE, eddy-current testing when ordered, dimensional checks and EN 10204 3.1 documentation when contracted. The final inspection scope must be agreed before order placement.

7. Is it suitable for the intended corrosive or high-temperature service?

TP304L is not a default choice for seawater, concentrated chlorides or strongly reducing acids. Corrosion selection must use actual fluid chemistry, temperature and crevice conditions. A material engineer should approve the final choice using actual service data.

8. What fabrication issues should be addressed?

Good weldability with qualified procedures. Control heat tint, purge quality and post-fabrication cleaning on wetted surfaces. Use a qualified procedure and preserve heat/lot traceability after cutting or fabrication.

9. What are typical applications?

Common candidate applications include shell-and-tube exchangers, condensers, food and beverage heat-transfer equipment, low-chloride utility service. These examples are not blanket design approvals.

10. What information is needed for a firm quotation?

Send standard and edition, grade/UNS, form, dimensions, condition, quantity, delivery destination, inspection/NDE, documentation, packing and any third-party inspection or code requirement.

Related Products
Send An Inquiry